Pig Indicator with Flange Connection

(0)

A pig signaller is a tool used in pipeline operations, typically mounted on pig launcher and receiver stations. It verifies the launch or arrival of pipeline pigs, and devices used for cleaning or inspecting pipelines, and can detect the passage of various types of pigs. The signaller is equipped with an interactive flag for real-time online checking of the trigger mechanism’s flexibility. The device features a flange connection, making installation easy, and the flange can be customized in size to suit any pipeline. Thus, the pig signaller is a versatile and essential tool for pipeline maintenance and inspection tasks.

Introduction

A pig indicator is a device that’s typically mounted on a pipeline. Installed directly onto the pipeline, pig indicator can detect the passage of various kinds of pipeline pigs, which are devices used for cleaning or inspecting pipelines. The pig indicator is equipped with an interactive flag that interfaces with the trigger mechanism.One of the key advantages of pig indicators is their easy installation process, facilitated by a flange connection. The flange, which can be customized into different sizes, ensures the pig indicator can be adapted to fit the requirements of an extensive range of pipelines. This makes the pig indicator a versatile tool for pipeline maintenance and inspection tasks.

pig indicator_1

Parameters

Brand Name
EMT
Product Name
Intrusive Pig Indicator
Flange Material
Stainless Steel 304、Stainless Steel 316、DSS F51、Carbon Steel A105N、Inconel 625
Flange Presure
class150#、class300#、class600#、class900#、class1500#、class2500#
Operating Temperater
-20℃ — +120℃
 

Basic Feature

                                    B                                              C                                     D
TypeIntrusive
 Indicator featureManual reset flagManual reset flag combined with electrical signalsDate and time display combined with electrical signals
Installing type2″Flange. As per ASME B16.5 (CLASS150~2500)
Plug body length _Correspond to total stand off200mm/Meet the actual needs
Insert depth adjustment20mm
Operating temperature-20~120℃/Meet customer requirements
NACE MR 0175Yes
Ingress protectionIP66
Explosion-proof classExdⅡ BT4ExdⅡ BT4
Remove under pressureNO
 
Optional Feature
Standard configuration             Optional configuration            — None
Trigger type (B-Bi-directional/U-Uni-directional*)●/○
Internal part material (316L SS/DSS/INCONEL)●/○/○
Flange/Body material(PTFE Coated A105N/304SS/316LSS/DSS/INCONEL/As per MR)●/○/○/○/○/○
The position of Internal liquid surface(High_Need to heat/Low_With no need for heating) [Only uni-directional pig detectors]●/○
Junction box material (Aluminium alloy/316SS)—/—○/●●/—
Switch type(DPDT/2*SPDT)—/—○/●○/●
Switch rating(DC24V 3A/DC24V 5A)—/—●/○●/—
Electrical connection size(M20×1.5(F)/1/2NPT(F))—/—●/○●/—
Standard configuration of Uni-directional trigger is ball shape.
Corresponding relations between trigger and Insert depth (In pipe)
Trigger type Bi-directional  Uni-directional
Insert depth (In pipe)21mm13mm
Faq Image
Pig Signaller

FAQ

Conduct regular inspections for signs of wear and tear or corrosion. Recalibrate the sensor periodically for accurate detection. If electronic, check the battery life and replace it as needed.

Maintenance for a pig signaller with flange connection is generally minimal but essential for optimal performance. Regular inspections should be conducted to check for any signs of wear and tear or corrosion. The sensor should also be recalibrated periodically to ensure accurate detection. If the device is electronic, make sure to check the battery life and replace it as needed.Important Information: Conduct regular inspections for signs of wear and tear or corrosion. Recalibrate the sensor periodically for accurate detection. If electronic, check the battery life and replace it as needed.